Suyuqlik bilan to'ldirilgan pastadir besleme yostig'iga o'rnatilgan transformator
Xizmat va xizmat ko'rsatish
Suyuqlik bilan to'ldirilgan pastadir besleme yostig'iga o'rnatilgan transformatorga texnik xizmat ko'rsatish davriy tekshiruvlar, yog 'darajasini tekshirish (moy bilan to'ldirilgan transformatorlar uchun) va himoya vositalarini sinovdan o'tkazishni o'z ichiga oladi. Muntazam texnik xizmat ko'rsatish optimal ishlashni ta'minlaydi va transformatorning ishlash muddatini uzaytiradi, uzilishlar va elektr ta'minotidagi uzilishlarni minimallashtiradi.
Mavjud ta'minot
|
Quvvat reytingi |
45kVA ~ 6000kVA |
|
Birlamchi kuchlanish ko'rsatkichlari |
35 kV gacha |
|
Ikkilamchi kuchlanish ko'rsatkichlari |
24,94 kV gacha |
|
HV teginish diapazoni |
±2×2,5% yoki boshqalar |
|
Ulanish turi |
Delta/Wye |
|
O'rash o'tkazgich |
Mis yoki alyuminiy |
|
TYPE |
Loop feed / Radial uzatish |
|
Konfiguratsiya |
Jonli old / o'lik old |
|
BIL |
30-150kV |
|
Standartlar |
ANSI, IEEE, DOE, CSA, NEMA, UL |
|
Ilova |
Turar joylar, mehmonxonalar, yakka tartibdagi uylar, parklar, tarqatish tizimlari |
|
Yog 'turi |
Mineral moy yoki biologik parchalanadigan tabiiy o'simlik yog'i, PCB bo'lmagan suyuqlik |
|
Tugatish rangi |
Bell Green yoki moslashtirilgan |
|
Qo'shimchalar reytingi |
NEMA 3R ob-havoga chidamli simli shkaf, muhrlangan tank |
UMUMIY
CSA standart topraklama qoidalari
CSA standartlariga muvofiq, uch fazali prokladkaga o'rnatilgan transformatorlar uchun topraklama qoidalari tank devoriga kamida 150 mm balandlikda yoki undan yuqori balandlikda payvandlangan ikkita vertikal o'rnatilgan tuproqli klemenslarni o'z ichiga oladi. Bitta terminal yuqori voltli tomonga, ikkinchisi esa past kuchlanishli tomonga o'rnatiladi. GrdY transformatorlari uchun yuqori voltli yon terminallar H0 bilan belgilanishi va belgilanishi kerak. Ikkala terminal ham bo'yalmagan, zanglamaydigan po'latdan yasalgan, kengligi 40 mm dan kam bo'lmagan va qalinligi 6 mm dan kam bo'lmagan bo'lishi kerak. Har bir terminalda bir-biridan 44,5 mm masofada joylashgan ikkita 14 mm (9/16 dyuym) teshik mavjud.
IEEE standart topraklama qoidalari
500 kVA va undan past bo'lgan transformatorlar uchun har birining 1/2% dyuymli 13 UNC teshigiga va minimal ip chuqurligi 11 mm (0,44 dyuym) bo'lgan ikkita po'lat prokladkalar berilishi kerak.
500 kVA dan yuqori transformatorlar uchun har birining oʻlchami 51 x 89 mm (2.0 x 3.5 dyuym) boʻlgan ikkita boʻyalmagan mis qoplamali poʻlat yoki zanglamaydigan poʻlat prokladkalar taʼminlanishi kerak. Har bir yostiqning markazlarida 44 mm (1,75 dyuym) oralig'ida joylashgan va 1/2% - dyuymli 13 UNC ip uchun urilgan ikkita teshik mavjud. Mis qoplamasining qalinligi 0,5 mm (0,02 dyuym) dan kam bo'lmasligi kerak va teshikning chuqurligi 13 mm (0,5 dyuym) dan kam bo'lmasligi kerak.
Suyuqlik bilan to'ldirilgan halqa besleme yostig'iga o'rnatilgan transformator Parametrlar
Quyidagi jadval suyuqlik bilan to'ldirilgan pastadir besleme pedi o'rnatilgan transformatorning standart parametridir. Agar sizga boshqa quvvat va kuchlanish darajalari kerak bo'lsa, aniq texnik parametrlar va takliflarni olish uchun TRANSpower bilan bog'laning.
Biz mijozlarga ko'ra moslashtirilgan suyuqlik bilan to'ldirilgan pastadir besleme pedi o'rnatilgan transformatorni taqdim etamiz.
Quyidagi Xususiyatlar FAQAT Malumot uchun.
|
Uch fazali pad o'rnatish transformatorlarining o'lchamlari |
||||||
|
kVA |
Turi |
HV |
LV |
Vt(mm) |
D(mm) |
H(mm) |
|
75 |
radial |
25000 Delta |
480GrdY/277 |
1280 |
1085 |
1085 |
|
150 |
halqa |
14400v |
600GrdY/347 |
1480 |
1250 |
1750 |
|
225 |
radial |
4160 Delta |
347GrdY/600V |
1480 |
1295 |
1750 |
|
300 |
halqa |
345000 |
208GrdY/120 |
1500 |
1730 |
1850 |
|
500 |
halqa |
1247Grdy/7200V |
600Y/347 |
1447 |
1800 |
1750 |
|
750 |
radial |
24940GrdY/14400 |
800GrdY/462 |
1485 |
1730 |
1750 |
|
1,000 |
radial |
249400DELTA |
480V |
1730 |
1350 |
1850 |
|
1,250 |
halqa |
25000V |
416V |
1730 |
1320 |
1920 |
|
1,500 |
halqa |
4160GRDY/2400 |
600GrdY/347 |
1730 |
1910 |
1965 |
|
1,500 |
halqa |
34500DELTA |
480GrdY/277 |
2220 |
2069 |
2065 |
|
1,750 |
halqa |
13800Delta |
480GrdY/277 |
1730 |
2304 |
1900 |
|
2,000 |
radial |
4160 DELTA |
415GrdY/240 |
1730 |
1950 |
1810 |
|
2,500 |
halqa |
25000 DELTA |
600GrdY/347 |
1730 |
2560 |
1960 |
|
2,550 |
halqa |
12470 DELTA |
415GrdY/240 |
1730 |
2000 |
2200 |
|
2600 |
Loop |
34500DELTA |
416GrdY/240 |
1730 |
1695 |
2290 |
|
3000 |
Loop |
27 600 DELTA |
13 800 DELTA |
1830 |
2360 |
2000 |
|
4000 |
halqa |
27600Delta |
600GrdY/347 |
1900 |
2500 |
2010 |
|
5000 |
radial |
13 800 DELTA |
4,160GrdY/2,400 |
1900 |
2735 |
2500 |
|
7000 |
halqa |
27 600 DELTA |
13 800 DELTA |
2200 |
3030 |
2080 |
|
7500 |
halqa |
249400DELTA |
4,16 kv |
2300 |
3200 |
2100 |
|
10000 |
halqa |
24900GrdY/14400 |
600V |
2800 |
3500 |
2560 |
Asosiy materiallar

Sinov va QC
Suyuqlik bilan to'ldirilgan pastadir besleme paneli o'rnatilgan transformatorning har bir birligi ishlab chiqarilgandan so'ng, ANSI/IEEE C57.12.90 va C57.12.00 talablari bo'yicha muntazam sinovlar/FAT o'tkaziladi. Sinov hisoboti IEEE/CSA standartlariga mos keladi va samaradorlik DOE 2016 standartlariga mos keladi.
Fabrikamızda marshrutlash testi
O'rash qarshiligi testi
Izolyatsiyaga chidamlilik sinovi
Kuchlanish nisbati xatosi sinovi
Qisqa tutashuv empedans sinovi
Yuksiz yo'qotish (Vatt) sinovi
Yukni yo'qotish (Vatt) testi
Induktsiyalangan kuchlanishga chidamlilik sinovi
Alohida manba kuchlanishiga chidamlilik sinovi
Bosimning yaxlitligi testi
Biz mijozlarimiz uchun ham onlayn, ham oflayn test nazorati imkoniyatlarini taklif etamiz. Shuningdek, guvohlar sinovi, sinov o'tkazilayotganda Transpower zavodiga tashrif buyurish uchun SGS, CSA yoki UL kabi uchinchi tomonni tanlashingiz va standart talablarga to'liq javob beradigan hisobotni olishingiz mumkin. Shu bilan bir qatorda, real vaqt rejimida test jarayonini kuzatish uchun onlayn video monitoringni so'rashingiz mumkin. Sinov jarayonlarida shaffoflik va ishonchni ta'minlash.
Bizning ishlab chiqarish va sinov uskunalarimiz har yili professional kalibrlashga ega.

fffffff



Bizning paketlarimiz va yuklarimiz
Yig'ish va qadoqlash maydoni


Yig'ilgandan keyin konteyner bilan jo'natish


Ilovalar
Bizning uch fazali pad o'rnatish transformatorlarimiz murakkabligi bo'yicha turli xil ilovalarda ishlatilishi mumkin.


Tez-tez so'raladigan savollar (FAQ)
Issiq teglar: suyuqlik bilan to'ldirilgan pastadir besleme yostig'i o'rnatilgan transformator, Xitoy suyuqlik bilan to'ldirilgan pastadir besleme yostig'i o'rnatilgan transformator ishlab chiqaruvchilari, etkazib beruvchilari, zavodi