Radial beslemeli prokladkaga o'rnatilgan transformator
Atrof-muhitga ta'siri
Radial beslemeli prokladkaga o'rnatilgan transformator atrof-muhitni hisobga olgan holda ishlab chiqilgan. Zamonaviy birliklar ko'pincha biologik parchalanadigan izolyatsion moylar yoki toksik bo'lmagan quruq turdagi izolyatsiya bilan to'ldiriladi, bu esa oqish yoki to'kilish holatlarida atrof-muhitga ta'sirni kamaytiradi.
Mavjud ta'minot
|
Quvvat reytingi |
45kVA ~ 6000kVA |
|
Birlamchi kuchlanish ko'rsatkichlari |
35 kV gacha |
|
Ikkilamchi kuchlanish ko'rsatkichlari |
24,94 kV gacha |
|
HV teginish diapazoni |
±2×2,5% yoki boshqalar |
|
Ulanish turi |
Delta/Wye |
|
O'rash o'tkazgich |
Mis yoki alyuminiy |
|
TYPE |
Loop feed / Radial uzatish |
|
Konfiguratsiya |
Jonli old / o'lik old |
|
BIL |
30-150kV |
|
Standartlar |
ANSI, IEEE, DOE, CSA, NEMA, UL |
|
Ilova |
Turar joylar, mehmonxonalar, yakka tartibdagi uylar, parklar, tarqatish tizimlari |
|
Yog 'turi |
Mineral moy yoki biologik parchalanadigan tabiiy o'simlik yog'i, PCB bo'lmagan suyuqlik |
|
Tugatish rangi |
Bell Green yoki moslashtirilgan |
|
Qo'shimchalar reytingi |
NEMA 3R ob-havoga chidamli simli shkaf, muhrlangan tank |
UMUMIY
Yostiqchaga o'rnatilgan transformatorlar har qanday joyda, jumladan, bino ichida, tashqarida va hatto ko'chalarda ham o'rnatilishi mumkin.
Yostiqqa o'rnatilgan transformatorni har doim tashqarida o'rnatish tavsiya etiladi; ammo, bu transformatorlarni istalgan joyga o'rnatish mumkin.
Ushbu turdagi uskunalar uchun umumiy nomlar suyuqlik bilan to'ldirilgan radial besleme yostig'iga o'rnatilgan yoki pastadir besleme yostig'iga o'rnatilgan transformatorlarni o'z ichiga oladi.
Parametrlar
Quyidagi jadval radial beslemeli prokladkaga o'rnatilgan transformatorning standart parametridir. Agar sizga boshqa quvvat va kuchlanish darajalari kerak bo'lsa, aniq texnik parametrlar va takliflarni olish uchun TRANSpower bilan bog'laning.
Biz mijozlarga ko'ra, radial besleme bilan moslashtirilgan pad o'rnatilgan transformatorni taqdim etamiz.
Quyidagi Xususiyatlar FAQAT Malumot uchun.
|
Uch fazali pad o'rnatish transformatorlarining o'lchamlari |
||||||
|
kVA |
Turi |
HV |
LV |
Vt(mm) |
D(mm) |
H(mm) |
|
75 |
radial |
25000 Delta |
480GrdY/277 |
1280 |
1085 |
1085 |
|
150 |
halqa |
14400v |
600GrdY/347 |
1480 |
1250 |
1750 |
|
225 |
radial |
4160 Delta |
347GrdY/600V |
1480 |
1295 |
1750 |
|
300 |
halqa |
345000 |
208GrdY/120 |
1500 |
1730 |
1850 |
|
500 |
halqa |
1247Grdy/7200V |
600Y/347 |
1447 |
1800 |
1750 |
|
750 |
radial |
24940GrdY/14400 |
800GrdY/462 |
1485 |
1730 |
1750 |
|
1,000 |
radial |
249400DELTA |
480V |
1730 |
1350 |
1850 |
|
1,250 |
halqa |
25000V |
416V |
1730 |
1320 |
1920 |
|
1,500 |
halqa |
4160GRDY/2400 |
600GrdY/347 |
1730 |
1910 |
1965 |
|
1,500 |
halqa |
34500DELTA |
480GrdY/277 |
2220 |
2069 |
2065 |
|
1,750 |
halqa |
13800Delta |
480GrdY/277 |
1730 |
2304 |
1900 |
|
2,000 |
radial |
4160 DELTA |
415GrdY/240 |
1730 |
1950 |
1810 |
|
2,500 |
halqa |
25000 DELTA |
600GrdY/347 |
1730 |
2560 |
1960 |
|
2,550 |
halqa |
12470 DELTA |
415GrdY/240 |
1730 |
2000 |
2200 |
|
2600 |
Loop |
34500DELTA |
416GrdY/240 |
1730 |
1695 |
2290 |
|
3000 |
Loop |
27 600 DELTA |
13 800 DELTA |
1830 |
2360 |
2000 |
|
4000 |
halqa |
27600Delta |
600GrdY/347 |
1900 |
2500 |
2010 |
|
5000 |
radial |
13 800 DELTA |
4,160GrdY/2,400 |
1900 |
2735 |
2500 |
|
7000 |
halqa |
27 600 DELTA |
13 800 DELTA |
2200 |
3030 |
2080 |
|
7500 |
halqa |
249400DELTA |
4,16 kv |
2300 |
3200 |
2100 |
|
10000 |
halqa |
24900GrdY/14400 |
600V |
2800 |
3500 |
2560 |
Asosiy materiallar

Sinov va QC
Radial beslemeli prokladkaga o'rnatilgan transformatorning har bir birligi ishlab chiqarilgandan so'ng, ANSI/IEEE C57.12.90 va C57.12.00 talablariga muvofiq muntazam sinovlar/FAT o'tkaziladi. Sinov hisoboti IEEE/CSA standartlariga mos keladi va samaradorlik DOE 2016 standartlariga mos keladi.
Fabrikamızda marshrutlash testi
O'rash qarshiligi testi
Izolyatsiyaga chidamlilik sinovi
Kuchlanish nisbati xatosi sinovi
Qisqa tutashuv empedans sinovi
Yuksiz yo'qotish (Vatt) sinovi
Yukni yo'qotish (Vatt) testi
Induktsiyalangan kuchlanishga chidamlilik sinovi
Alohida manba kuchlanishiga chidamlilik sinovi
Bosimning yaxlitligi testi
Biz mijozlarimiz uchun ham onlayn, ham oflayn test nazorati imkoniyatlarini taklif etamiz. Shuningdek, guvohlar sinovi, sinov o'tkazilayotganda Transpower zavodiga tashrif buyurish uchun SGS, CSA yoki UL kabi uchinchi tomonni tanlashingiz va standart talablarga to'liq javob beradigan hisobotni olishingiz mumkin. Shu bilan bir qatorda, real vaqt rejimida test jarayonini kuzatish uchun onlayn video monitoringni so'rashingiz mumkin. Sinov jarayonlarida shaffoflik va ishonchni ta'minlash.
Bizning ishlab chiqarish va sinov uskunalarimiz har yili professional kalibrlashga ega.

Radial beslemeli prokladkaga o'rnatilgan transformator Kontur


Rasm

Bizning paketlarimiz va yuklarimiz
Yig'ish va qadoqlash maydoni


Yig'ilgandan keyin konteyner bilan jo'natish


Ilovalar
Bizning uch fazali pad o'rnatish transformatorlarimiz murakkabligi bo'yicha turli xil ilovalarda ishlatilishi mumkin.


Tez-tez so'raladigan savollar (FAQ)
Issiq teglar: Radial beslemeli prokladkaga o'rnatilgan transformator, Xitoyda radiusli o'rnatilgan transformator ishlab chiqaruvchilar, etkazib beruvchilar, zavod